About 843,000 results
Open links in new tab
  1. What is the difference between baud rate and bit rate?

    Dec 12, 2013 · Baud rate is mostly used in telecommunication and electronics, representing symbol per second or pulses per second, whereas bit rate is simply bit per second. To be …

  2. Baud rate vs. Bit rate - Electrical Engineering Stack Exchange

    However, each baud (signal change) can encode more than 1 bit. Baud 115200 means 115200 bits per second only if each baud = 1 bit. If each baud is 5 bits, then having baud 115200 …

  3. What standard UART rates are there?

    In practice a 16 bit counter plus pre/post scalers is more than sufficient to get "close enough" to arbitrary baud rates. UART serial can tolerate slight baud rate mismatches.

  4. A COM Port on a Windows PC indicates the bit rate, or the Baud …

    Feb 27, 2016 · Despite being marked "bits per second", that dialog actually displays baud as a rate in symbols per second. (Symbols include data bits but also start, stop, and parity. For …

  5. How to change default baud rate of serial monitor in VSCode with ...

    If you continue to get a default baud rate of 9600 in platformio, even though you set monitor_speed=115200 in platform.ini file, check the button "Switch PlatformIO Project …

  6. How were standard serial port baud rates chosen?

    Sep 22, 2023 · How were standard serial port baud rates chosen? 1200, 9600, 115200, aren't the numbers we'd expect (powers of 2 or 10), but don't seem random either. Wikipedia states …

  7. can bus - how to calculate the CAN bus baud rate from the Tq and …

    Mar 23, 2022 · first , I think I know how to calculate the CAN bus Baud rate form the parameter in picture blew ,this is a CAN FD config. clock frequency :80000 k pre-scaler :1 so we can get …

  8. Windows CMD - Find current baud rate of COM port

    Mar 12, 2021 · Windows CMD - Find current baud rate of COM port Asked 4 years, 9 months ago Modified 4 years, 9 months ago Viewed 10k times

  9. baudrate - UART: How to calculate bit time? - Electrical …

    Dec 17, 2021 · 0 Reading this application note about timing for enable RS485 transeiver, I read that I need to ensure a time called "bit time", which depends on the baud rate, for example the …

  10. RS485 at 115200 - Electrical Engineering Stack Exchange

    Mar 11, 2025 · No, RS-485 at 115,200 baud is in general terms a perfectly good idea. Most resources say that at this speed, you'll be limited to 1,200 metres -- but anywhere near this …