  1. Romex connectors - Electrician Talk

    Oct 14, 2021 · The plastic connectors work fine, only really need some edge protection on the KO, not like people will be repelling from the romex.

  2. How to remove T&B 3201 Romex Connectors - Electrician Talk

    Dec 13, 2014 · Does anyone know how to take a t&b 3201 plastic romex connector off of the cable? Rewiring a panel and need to remove them.

  3. NM connector for threaded outdoor box - Electrician Talk

    Nov 11, 2023 · I am looking for a solution to an issue I have. I often need to bring 6-2 romex into the back of a 2-gang outdoor box with 3/4” threaded KOs. I can use a typical 2-screw Romex squeeze …

  4. Plastic NM Connectors - Electrician Talk

    Sep 26, 2012 · I never like the plastic Romex Connectors, but today I had some much trouble with the metal connectors and a CH-CH Panel because the nuts would not fit because of not enough room in …

  5. Romex into surface mounted outdoor box. - Electrician Talk

    Dec 9, 2018 · A button connector won't work since the 1/2" KO in the box is threaded. A typical metal 2-screw romex squeeze connector works, but it requires a 1-1/2" hole in the brick to accommodate it's …

  6. MC cable and duplex connectors - Electrician Talk

    Mar 22, 2007 · Regarding the difference between a Romex connector and an MC cable connector, the hole is there because UL514B requires a cable stop feature that will prevent the outer sheathing from …

  7. Residential Best Practices, Adding Outside Receptacle

    Oct 31, 2024 · Nooooooo!!!!!! Arrrrggghhh!!! Sorry for the over-reaction. Remove the plastic box. Drill from the outside-in or your wall will spall. Drill it right behind or in the same space. Use Romex if you …

  8. Halo recess lights OR plastic Romex connectors - Electrician Talk

    Feb 15, 2018 · Recently installed some Halo 99 4 inch recces lights and had a hard time getting plastic connectors in. I typically use black buttons from Arlington but...

  9. Plastic bushings on rigid - always a requirement? - Electrician Talk

    Apr 12, 2023 · Example: 3/4" EMT connector doesn't need a plastic bushing, but a 3/4" rigid nipple does? Am I reading this correctly that any RMC threads must be protected by a bushing? I had heard …

  10. Two Romex cables through one connector? - DoItYourself.com

    Oct 25, 2010 · Halex this is a 3/8 connector rate for 2 cables When I said two pair, I didn't mean 4 cables, only 2 complete 12/2 cables. I will have to go check what I was looking at today. It had …